「에너지 정책 및 보전법」 (제323조 [미국법전 제42편제6293조])
• 국가‧지역: 미국 • 법률번호: 공법 제94-163호(제정), 공법 제117-58호(개정) 미국법전 제19편제77장(현행) • 제정일: 1975년 12월 22일 • 개정일: 2021년 11월 15일
United States Code Title 42-THE PUBLIC HEALTH AND WELFARE CHAPTER 77-ENERGY CONSERVATION SUBCHAPTER III-IMPROVING ENERGY EFFICIENCY Part A-Energy Conservation Program for Consumer Products Other Than Automobiles 미국법전 제42편 공중보건 및 복지 제77장 에너지보전 제3절 에너지효율 개선 제1관 자동차 외 소비자 제품의 에너지절약제도
(a) General rule All test procedures and related determinations prescribed or made by the Secretary with respect to any covered product (or class thereof) which are in effect on March 17, 1987, shall remain in effect until the Secretary amends such test procedures and related determinations under subsection (b). (b) Amended and new procedures (1) TEST PROCEDURES.— (A) AMENDMENT.—At least once every 7 years, the Secretary shall review test procedures for all covered products and— (i) amend test procedures with respect to any covered product, if the Secretary determines that amended test procedures would more accurately or fully comply with the requirements of paragraph (3); or (ii) publish notice in the Federal Register of any determination not to amend a test procedure. (B) The Secretary may, in accordance with the requirements of this subsection, prescribe test procedures for any consumer product classified as a covered product under section 6292(b) of this title. (C) The Secretary shall direct the National Institute of Standards and Technology to assist in developing new or amended test procedures. (2) If the Secretary determines, on his own behalf or in response to a petition by any interested person, that a test procedure should be prescribed or amended, the Secretary shall promptly publish in the Federal Register proposed test procedures and afford interested persons an opportunity to present oral and written data, views, and arguments with respect to such procedures. The comment period shall not be less than 60 days and may be extended for good cause shown to not more than 270 days. In prescribing or amending a test procedure, the Secretary shall take into account such information as the Secretary determines relevant to such procedure, including technological developments relating to energy use or energy efficiency of the type (or class) of covered products involved. (3) Any test procedures prescribed or amended under this section shall be reasonably designed to produce test results which measure energy efficiency, energy use, water use (in the case of showerheads, faucets, water closets and urinals), or estimated annual operating cost of a covered product during a representative average use cycle or period of use, as determined by the Secretary, and shall not be unduly burdensome to conduct. (4) If the test procedure is a procedure for determining estimated annual operating costs, such procedure shall provide that such costs shall be calculated from measurements of energy use or, in the case of showerheads, faucets, water closets, or urinals, water use in a representative average use cycle or period of use, as determined by the Secretary, and from representative average unit costs of the energy needed to operate such product during such cycle, or in the case of showerheads, faucets, water closets, or urinals, representative average unit costs of water and wastewater treatment service resulting from the operation of such products during such cycle. The Secretary shall provide information to manufacturers with respect to representative average unit costs of energy, water, and wastewater treatment. (5) With respect to fluorescent lamp ballasts manufactured on or after January 1, 1990, and to which standards are applicable under section 6295 of this title, the Secretary shall prescribe test procedures that are in accord with ANSI standard C82.2–1984 or other test procedures determined appropriate by the Secretary. (6) With respect to fluorescent lamps and incandescent reflector lamps to which standards are applicable under subsection (i) of section 6295 of this title, the Secretary shall prescribe test procedures, to be carried out by accredited test laboratories, that take into consideration the applicable IES or ANSI standard. (7)(A) Test procedures for showerheads and faucets to which standards are applicable under subsection (j) of section 6295 of this title shall be the test procedures specified in ASME A112.18.1M–1989 for such products. (B) If the test procedure requirements of ASME A112.18.1M–1989 are revised at any time and approved by ANSI, the Secretary shall amend the test procedures established by subparagraph (A) to conform to such revised ASME/ANSI requirements unless the Secretary determines, by rule, that to do so would not meet the requirements of paragraph (3). (8)(A) Test procedures for water closets and urinals to which standards are applicable under subsection (k) of section 6295 of this title shall be the test procedures specified in ASME A112.19.6–1990 for such products. (B) If the test procedure requirements of ASME A112.19.6–1990 are revised at any time and approved by ANSI, the Secretary shall amend the test procedures established by subparagraph (A) to conform to such revised ASME/ANSI requirements unless the Secretary determines, by rule, that to do so would not meet the requirements of paragraph (3). (9) Test procedures for illuminated exit signs shall be based on the test method used under version 2.0 of the Energy Star program of the Environmental Protection Agency for illuminated exit signs. (10)(A) Test procedures for distribution transformers and low voltage dry type distribution transformers shall be based on the "Standard Test Method for Measuring the Energy Consumption of Distribution Transformers" prescribed by the National Electrical Manufacturers Association (NEMA TP 2–1998). (B) The Secretary may review and revise the test procedures established under subparagraph (A). (C) For purposes of section 6317(a) of this title, the test procedures established under subparagraph (A) shall be considered to be the testing requirements prescribed by the Secretary under section 6317(a)(1) of this title for distribution transformers for which the Secretary makes a determination that energy conservation standards would— (i) be technologically feasible and economically justified; and (ii) result in significant energy savings. (11) Test procedures for traffic signal modules and pedestrian modules shall be based on the test method used under the Energy Star program of the Environmental Protection Agency for traffic signal modules, as in effect on August 8, 2005. (12)(A) Test procedures for medium base compact fluorescent lamps shall be based on the test methods for compact fluorescent lamps used under the August 9, 2001, version of the Energy Star program of the Environmental Protection Agency and the Department of Energy. (B) Except as provided in subparagraph (C), medium base compact fluorescent lamps shall meet all test requirements for regulated parameters of section 6295(cc)† of this title. (C) Notwithstanding subparagraph (B), if manufacturers document engineering predictions and analysis that support expected attainment of lumen maintenance at 40 percent rated life and lamp lifetime, medium base compact fluorescent lamps may be marketed before completion of the testing of lamp life and lumen maintenance at 40 percent of rated life. (13) Test procedures for dehumidifiers shall be based on the test criteria used under the Energy Star Program Requirements for Dehumidifiers developed by the Environmental Protection Agency, as in effect on August 8, 2005, unless revised by the Secretary pursuant to this section. (14) The test procedure for measuring flow rate for commercial prerinse spray valves shall be based on American Society for Testing and Materials Standard F2324, entitled "Standard Test Method for Pre-Rinse Spray Valves". (15) The test procedure for refrigerated bottled or canned beverage vending machines shall be based on American National Standards Institute/American Society of Heating, Refrigerating and Air-Conditioning Engineers Standard 32.1–2004, entitled "Methods of Testing for Rating Vending Machines for Bottled, Canned or Other Sealed Beverages". (16)(A)(i) Test procedures for ceiling fans shall be based on the "Energy Star Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR Qualified Ceiling Fans, Version 1.1" published by the Environmental Protection Agency. (ii) Test procedures for ceiling fan light kits shall be based on the test procedures referenced in the Energy Star specifications for Residential Light Fixtures and Compact Fluorescent Light Bulbs, as in effect on August 8, 2005. (B) The Secretary may review and revise the test procedures established under subparagraph (A). (17) CLASS A EXTERNAL POWER SUPPLIES.—Test procedures for class A external power supplies shall be based on the "Test Method for Calculating the Energy Efficiency of Single-Voltage External AC–DC and AC–AC Power Supplies" published by the Environmental Protection Agency on August 11, 2004, except that the test voltage specified in section 4(d) of that test method shall be only 115 volts, 60 Hz. (18) METAL HALIDE LAMP BALLASTS.—Test procedures for metal halide lamp ballasts shall be based on ANSI Standard C82.6–2005, entitled "Ballasts for High Intensity Discharge Lamps—Method of Measurement". (c) Restriction on certain representations (1) No manufacturer, distributor, retailer, or private labeler may make any representation— (A) in writing (including a representation on a label); or (B) in any broadcast advertisement, with respect to the energy use or efficiency or, in the case of showerheads, faucets, water closets, and urinals, water use of a covered product to which a test procedure is applicable under subsection (a) or the cost of energy consumed by such product, unless such product has been tested in accordance with such test procedure and such representation fairly discloses the results of such testing. (2) Effective 180 days after an amended or new test procedure applicable to a covered product is prescribed or established under subsection (b), no manufacturer, distributor, retailer, or private labeler may make any representation— (A) in writing (including a representation on a label); or (B) in any broadcast advertisement, with respect to energy use or efficiency or, in the case of showerheads, faucets, water closets, and urinals, water use of such product or cost of energy consumed by such product, unless such product has been tested in accordance with such amended or new test procedures and such representation fairly discloses the results of such testing. (3) On the petition of any manufacturer, distributor, retailer, or private labeler, filed not later than the 60th day before the expiration of the period involved, the 180-day period referred to in paragraph (2) may be extended by the Secretary with respect to the petitioner (but in no event for more than an additional 180 days) if the Secretary determines that the requirements of paragraph (2) would impose an undue hardship on such petitioner. (d) Case in which test procedure is not required (1) The Secretary is not required to publish and prescribe test procedures for a covered product (or class thereof) if the Secretary determines, by rule, that test procedures cannot be developed which meet the requirements of subsection (b)(3) and publishes such determination in the Federal Register, together with the reasons therefor. (2) For purposes of section 6297 of this title, a determination under paragraph (1) with respect to any covered product or class shall have the same effect as would a standard prescribed for a covered product (or class). (e) Amendment of standard (1) In the case of any amended test procedure which is prescribed pursuant to this section, the Secretary shall determine, in the rulemaking carried out with respect to prescribing such procedure, to what extent, if any, the proposed test procedure would alter the measured energy efficiency, measured energy use, or measured water use of any covered product as determined under the existing test procedure. (2) If the Secretary determines that the amended test procedure will alter the measured efficiency or measured use, the Secretary shall amend the applicable energy conservation standard during the rulemaking carried out with respect to such test procedure. In determining the amended energy conservation standard, the Secretary shall measure, pursuant to the amended test procedure, the energy efficiency, energy use, or water use of a representative sample of covered products that minimally comply with the existing standard. The average of such energy efficiency, energy use, or water use levels determined under the amended test procedure shall constitute the amended energy conservation standard for the applicable covered products. (3) Models of covered products in use before the date on which the amended energy conservation standard becomes effective (or revisions of such models that come into use after such date and have the same energy efficiency, energy use, or water use characteristics) that comply with the energy conservation standard applicable to such covered products on the day before such date shall be deemed to comply with the amended energy conservation standard. (4) The Secretary's authority to amend energy conservation standards under this subsection shall not affect the Secretary's obligation to issue final rules as described in section 6295 of this title. (f) Additional consumer and commercial products (1) Not later than 2 years after August 8, 2005, the Secretary shall prescribe testing requirements for refrigerated bottled or canned beverage vending machines. (2) To the maximum extent practicable, the testing requirements prescribed under paragraph (1) shall be based on existing test procedures used in industry. (Pub. L. 94–163, title III, §323, Dec. 22, 1975, 89 Stat. 919; Pub. L. 95–619, title IV, §§421, 425(a), title VI, §691(b)(2), Nov. 9, 1978, 92 Stat. 3257, 3265, 3288; Pub. L. 100–12, §4, Mar. 17, 1987, 101 Stat. 105; Pub. L. 100–357, §2(c), June 28, 1988, 102 Stat. 672; Pub. L. 100–418, title V, §5115(c), Aug. 23, 1988, 102 Stat. 1433; Pub. L. 102–486, title I, §123(d), Oct. 24, 1992, 106 Stat. 2821; Pub. L. 109–58, title I, §135(b), Aug. 8, 2005, 119 Stat. 627; Pub. L. 110–140, title III, §§301(b), 302(a), 324(c), Dec. 19, 2007, 121 Stat. 1550, 1551, 1593.)
「에너지 정책 및 보전법」 (제323조 [미국법전 제42편제6293조])
• 국가‧지역: 미국 • 법률번호: 공법 제94-163호(제정), 공법 제117-58호(개정) 미국법전 제19편제77장(현행) • 제정일: 1975년 12월 22일 • 개정일: 2021년 11월 15일
United States Code Title 42-THE PUBLIC HEALTH AND WELFARE CHAPTER 77-ENERGY CONSERVATION SUBCHAPTER III-IMPROVING ENERGY EFFICIENCY Part A-Energy Conservation Program for Consumer Products Other Than Automobiles 미국법전 제42편 공중보건 및 복지 제77장 에너지보전 제3절 에너지효율 개선 제1관 자동차 외 소비자 제품의 에너지절약제도
① 통칙 대상 제품(또는 대상 제품군)에 대하여 장 관이 정한 모든 시험 절차 및 그와 관련하 여 내린 판단으로서 1987년 3월 17일 기준 유효한 것은 장관이 그 시험 절차 및 관련 판단을 제2항에 따라 개정할 때까지 계속 하여 유효하다. ② 절차의 개정 및 신설 1. 시험 절차 가. 개정. 장관은 최소한 7년에 한 번, 모 든 대상 제품의 시험 절차를 검토하고 다음의 어느 하나와 같이 하여야 한다. 1) 장관이 시험 절차를 개정하여 제 3호의 요건을 더욱 정확히 또는 온전히 준수할 수 있다고 판단하 는 때는, 대상 제품의 시험 절차를 개정 2) 시험 절차를 개정하지 아니하기 로 한 판단을 관보에 게재 나. 장관은 이 항의 요건을 준수하여, 이 편 제6292조제2항에서 대상 제품으로 분류하는 소비자 제품의 시험 절차를 정할 수 있다. 다. 장관은 신설 또는 개정 시험 절차의 수립을 지원하도록 미국표준기술연구 소에 지시하여야 한다. 2. 장관이 직권으로 또는 이해관계인의 신 청에 따라, 어느 한 시험 절차를 정하거 나 개정할 필요가 있다고 판단하면, 장관 은 시험 절차안을 신속히 관보에 게재하 고 이해관계인이 해당 절차안에 대한 자 료, 의견 및 주장을 구두나 서면으로 제 출할 수 있도록 기회를 제공하여야 한다. 의견 수렴 기간은 60일 이상이어야 하며 타당한 사유가 있으면 270일 이내로 이 를 연장할 수 있다. 장관은 시험 절차를 정하거나 개정할 때, 해당하는 대상 제품 종류(또는 제품군)의 에너지사용량이나 에너지효율과 관련한 기술발전 등, 해당 절차와 관련이 있다고 판단하는 정보를 고려하여야 한다. 3. 이 조에 따라 정하거나 개정하는 시험 절차는 장관이 정하는 대표적 평균 사용 주기나 사용기간 동안 대상 제품의 에너 지효율, 에너지사용량, 사용수량(샤워헤 드, 수도꼭지, 수세식변기와 소변기에 적 용함) 또는 연간에너지비용 등을 측정하 는 시험 결과를 도출하도록 합리적으로 설계하여야 하며, 그 수행이 과도한 부담 이 되지 아니하여야 한다. 4. 시험 절차가 연간에너지비용을 결정하 기 위한 절차일 때는, 그 비용의 산정이 장관이 정하는 대표적 평균 사용주기나 사용기간 동안의 에너지사용량 측정, 또 는 샤워헤드·수도꼭지·수세식변기·소변 기의 사용수량 측정에 기초하는 한편, 해 당 제품을 그러한 주기 동안 가동하는 데 필요한 에너지의 대표적 평균 단가, 또는 샤워헤드·수도꼭지·수세식변기·소변기를 그 주기 동안 가동함으로써 발생하는 상 하수도의 대표적 평균 단가에 기초하도 록 해당 절차를 정하여야 한다. 장관은 에너지와 상하수도의 대표적 평균 단가 정보를 제조업자에게 제공하여야 한다. 5. 1990년 1월 1일 이후 제조된 형광램프 용 안정기 중 이 편 제6295조의 기준이 적용되는 제품에 대하여, 장관은 미국표 준협회(ANSI) 기준 C82.2-1984에 따 른 시험 절차나 그 밖에 장관이 적절하다 고 판단하는 시험 절차를 정하여야 한다. 6. 이 편 제6295조제9항의 기준이 적용되 는 형광램프와 백열전구에 대하여, 장관 은 관련 조명기술자협회(IES)나 미국표 준협회 기준을 고려하여, 인증시험기관 에서 수행하여야 하는 시험 절차를 정하 여야 한다. 7. 가. 이 편 제6295조제10항의 기준이 적 용되는 샤워헤드와 수도꼭지에 대한 시험 절차는 그러한 제품에 대하여 미 국기계학회(ASME) 기준 A112.18.1M-1989에서 정하는 시험 절차로 한다. 나. 언제든지 미국기계학회 기준 A122.18.1M-1989의 시험 절차 요건 이 수정되고 미국표준협회가 이를 승 인하면, 장관은 가목에 따라 신설한 시 험 절차가 수정된 미국기계학회/미국 표준협회 요건에 부합하도록 이를 개 정하여야 한다. 다만, 그러함으로써 제 3호의 요건에 따르지 못하게 된다고 장관이 규칙으로 판단하는 때는 그러 하지 아니하다. 8. 가. 이 편 제6295조제11항의 기준이 적 용되는 수세식변기와 소변기에 대한 시험 절차는 그러한 제품에 대하여 미 국기계학회 기준 A112.19.6-1990에 서 정하는 시험 절차로 한다. 나. 언제든지 미국기계학회 기준 A112.19.6-1990의 시험 절차 요건이 수정되고 미국표준협회가 이를 승인하 면, 장관은 가목에 따라 신설한 시험 절차가 수정된 미국기계학회/미국표준 협회 요건에 부합하도록 이를 개정하 여야 한다. 다만, 그러함으로써 제3호 의 요건에 따르지 못하게 된다고 장관 이 규칙으로 판단하는 때는 그러하지 아니하다. 9. 비상구 유도등에 대한 시험 절차는 비상 구 유도등에 대하여 환경보호청의 에너 지스타제도 2.0에 따라 사용되는 시험법 에 기초하여야 한다. 10. 가. 배전용 변압기와 저압 건식 배전용 변압기에 대한 시험 절차는 미국전기 공업협회(NEMA)에서 정하는 "배전 용 변압기 에너지소비량 측정 표준시 험법"(미국전기공업협회 기준 TP 2 1998)에 기초하여야 한다. 나. 장관은 가목에 따라 신설하는 시험 절차를 검토하여 수정할 수 있다. 다. 이 편 제6317조제1항의 목적상, 가목 에 따라 신설하는 시험 절차는, 에너지 절약기준이 다음에 모두 해당한다고 장관이 판단한 배전용 변압기에 대하 여, 이 편 제6317조제1항제1호에 따 라 장관이 정하는 시험 절차로 본다. 1) 기술적으로 실현가능하며 경제적 으로 타당할 것 2) 현저한 에너지 절약 효과가 있을 것 11. 교통신호등과 보행신호등에 대한 시험 절차는, 2005년 8월 8일에 시행 중인, 교 통신호등에 대하여 환경보호청의 에너지 스타제도에 따라 사용되는 시험법에 기 초하여야 한다. 12. 가. 병형베이스 콤팩트형 형광램프에 대한 시험 절차는 환경보호청과 에너 지부의 2001년 8월 9일 자 에너지스 타제도에 따라 사용되는 콤팩트형 형 광램프 시험법에 기초하여야 한다. 나. 다목에서 정하는 바를 제외하고, 병 형베이스 콤팩트형 형광램프는 이 편 제6295조제29항†의 규제 한도에 해당 하는 모든 시험 요건을 충족하여야 한 다. 다. 나목에도 불구하고, 제조업자가 정격 수명과 전구수명의 40퍼센트에서 달 성할 것으로 예상되는 광속유지율에 대한 공학적 예측과 분석을 기록으로 남긴 때는, 전구수명 시험 및 정격수명 40퍼센트에서의 광속유지율 시험을 완료하기 전에 병형베이스 콤팩트형 형광램프를 출시할 수 있다. 13. 제습기에 대한 시험 절차는, 장관이 이 조에 따라 수정하는 때를 제외하고, 환경 보호청이 수립하여 2005년 8월 8일에 시 행 중인 "제습기 에너지스타제도 요건"에 따라 사용하는 시험 기준에 기초하여야 한다. 14. 상업용 예비세척 물분무헤드의 토수량 을 측정하기 위한 시험 절차는 미국재료 시험협회 기준 F2324 "예비세척 물분무 헤드 표준시험법"에 기초하여야 한다. 15. 냉장 병·캔 음료 자동판매기에 대한 시 험 절차는 "병, 캔, 기타 밀봉 음료 자판 기 정격 시험법"인 미국표준협회/미국난 방냉장공조기술자협회 기준 32.1-2004 에 기초하여야 한다. 16. 가. 1) 천장형 선풍기에 대한 시험 절 차는 환경보호청에서 발행한 "에 너지스타 시험 시설 지침: 에너지 스타 적합 천장형 선풍기 시험 시 설의 구축 및 주(州)별 시험법의 충실 이행, 제1.1판"에 기초하여 야 한다. 2) 천장형 선풍기가 달린 조명기구 에 대한 시험 절차는 2005년 8월 8일에 시행 중인 "주택용 조명기 구 및 콤팩트형 형광전구의 에너 지스타 규격"에서 인용하는 시험 절차에 기초하여야 한다. 나. 장관은 가목에 따라 신설하는 시험 절차를 검토하여 수정할 수 있다. 17. A형 외장형 전원장치. A형 외장형 전 원장치에 대한 시험 절차는 환경보호청 이 2004년 8월 11일에 발행한 "단일출력 전압 외장형 직류 및 교류 전원장치의 에 너지효율 산정 시험법"에 기초하도록 하 되, 이 시험법 제4조제4항의 시험 전압은 전압 115볼트, 주파수 60헤르츠(Hz)로 만 한다. 18. 메탈핼라이드램프용 안정기. 메탈핼라 이드램프용 안정기에 대한 시험 절차는 미국표준협회 기준 C82.6-2005 "고휘 도 방전 램프용 안정기—측정법"에 기초 하여야 한다. ③ 특정 표시의 제한 1. 제조업자, 유통업자, 소매업자 또는 자 체상표 소유자는 에너지사용량이나 에너 지효율, 또는 샤워헤드·수도꼭지·수세식 변기·소변기에 대하여는 제1항에 따른 시험 절차가 적용되는 대상 제품의 사용 수량 또는 그러한 제품이 소비하는 에너 지비용과 관련하여 다음 각 목의 어느 하 나에 해당하는 형태의 표시를 하여서는 아니 된다. 다만, 제품이 해당 시험 절차 에 따라 시험을 마쳤고 표시가 그 시험 결과를 공정하게 나타내는 때는 그러하 지 아니하다. 가. 문서로 하는 표시(표장에 하는 표시 를 포함한다) 나. 방송광고로 하는 표시 2. 대상 제품에 대하여 제2항에 따라 시험 절차를 개정하거나 신설하는 날부터 180 일이 지난 때, 제조업자, 유통업자, 소매 업자 또는 자체상표 소유자는 에너지사 용량이나 에너지효율, 또는 샤워헤드·수 도꼭지·수세식변기·소변기에 대하여는 해당 제품의 사용수량 또는 그러한 제품 이 소비하는 에너지비용과 관련하여 다 음 각 목의 어느 하나에 해당하는 형태의 표시를 하여서는 아니 된다. 다만, 제품 이 개정되거나 신설된 시험 절차에 따라 시험을 마쳤고 표시가 그 시험 결과를 공 정하게 나타내는 때는 그러하지 아니하 다. 가. 문서로 하는 표시(표장에 하는 표시 를 포함한다) 나. 방송광고로 하는 표시 3. 해당하는 기한이 도래하기 전의 60일 이 내에 제조업자, 유통업자, 소매업자 또는 자체상표 소유자가 청원을 제기한 때는, 장관이 볼 때 제2호의 요건이 청원인에 게 과도한 부담을 지운다고 판단되면, 장 관은 제2호에 언급된 180일의 기간을 그 청원인에 대하여 연장할 수 있다(다만, 어느 상황에서든지 180일 이내로 연장). ④ 시험 절차가 필요하지 아니한 때 1. 장관이 제2항제3호의 요건을 충족하는 시험 절차를 수립할 수 없다고 판단하는 규칙을 그 사유와 함께 관보에 게재하면, 장관은 대상 제품(또는 그 제품군)에 대 한 시험 절차를 정하여 게재할 의무를 지 지 아니한다. 2. 이 편 제6297조의 목적상, 대상 제품 또 는 제품군과 관련한 제1호의 판단은 어 느 한 대상 제품 또는 제품군에 대하여 정하는 기준과 같은 효력을 가진다. ⑤ 표준의 개정 1. 장관은 이 조에 따라 정한 시험 절차를 개정할 때, 시험 절차의 개정안으로 인하 여 기존의 시험 절차로 결정된 대상 제품 의 에너지효율 측정, 에너지사용량 측정, 또는 사용수량 측정에 변동이 발생할 때 는, 그 개정안에 대한 입법 절차 중에, 그 변동이 어느 정도일지를 판단하여야 한 다. 2. 장관은 시험 절차의 개정으로 인하여 측 정 효율이나 측정 사용량에 변동이 발생 할 것이라 판단하는 때는, 그 시험 절차 에 대한 입법 절차 중에, 관련 에너지절 약기준을 개정하여야 한다. 개정 에너지 절약기준을 정할 때, 장관은 현행 기준을 최소한으로 준수하는 대상 제품 시료의 에너지효율, 에너지사용량 또는 사용수 량을 개정 시험 절차에 따라 측정하여야 한다. 개정 시험 절차에 따라 결정되는 에너지효율, 에너지사용량 또는 사용수 량 수준의 평균은 해당하는 대상 제품에 대한 개정 에너지절약기준을 구성한다. 3. 개정 에너지절약기준의 시행일 전에 사 용 중인 대상 제품의 모델로서(또는 그 시행일 후에 사용되는 추가모델로서 에 너지효율, 에너지사용량 또는 사용수량 등의 특성이 기존과 동일한 것) 그 시행 일 전에 대상 제품에 적용되는 에너지절 약기준을 준수하는 모델은 개정 에너지 절약기준을 준수하는 것으로 본다. 4. 이 항에 따라 에너지절약기준을 개정할 장관의 권한은 이 편 제6295조에 따라 확정 규칙을 발표하여야 하는 장관의 의 무에 영향을 주지 아니한다. ⑥ 추가 소비자 및 상업용 제품 1. 2005년 8월 8일부터 2년 이내에, 장관 은 냉장 병·캔 음료 자판기에 대한 시험 요건을 정하여야 한다. 2. 실행 가능한 한 최대로, 제1호의 시험 요 건은 업계에서 사용하는 기존의 시험 절 차에 기초하여야 한다. (공법 제94-163호 제3편 제323조, 1975.12.22., 법령 집번호 제89-919호; 공법 제95-619호 제4편 제421 조·제425조제1항, 제6편 제691조제2항제2호, 1978.11.9., 법령집번호 제92-3267호, 3265호, 3288 호; 공법 제100-12호 제4조, 1987.3.17., 법령집번호 제101-105호; 공법 제100-357호 제2조제3항, 1988.6.28., 법령집번호 제102-672호; 공법 제100 418호 제5편 제5115조제3항, 1988.8.23., 법령집번호 제102-1433호; 공법 제102-486호 제1편 제123조제 4항, 1992.10.24., 법령집번호 제106-2821호; 공법 제 109-58호 제1편 제135조제2항, 2005.8.8., 법령집번 호 제119-627호; 공법 제110-140호 제3편 제301조 제2항·제302조제1항·제324조제3항, 2007.12.19., 법령 집번호 제121-1550호, 1551호, 1593호.)